SECTION
10520
PLASTIC LOCKERS
1.01
SECTION
INCLUDES
A.
Solid
plastic lockers.
B.
Solid
plastic bench lockers.
C.
Solid
plastic cubby lockers.
D.
Pedestal
benches.
E. Hardware and accessories.
1.02
RELATED
SECTIONS
A.
Section
(select Sections that describe the
anchoring substrate: floor and/or walls).
1.03
REFERENCES
A.
1.04
SUBMITTALS
A.
Provide
submittals in accordance with Conditions of the Contract and Section
01330-Submittal Procedures.
B.
Submit
shop drawings showing locker plan layout, numbering plan, profiles, and product
components, including anchorage, accessories and finish colors.
C.
Submit
product data on locker construction, hardware, and accessories.
D.
Submit
two samples 4 x 4 inch (100 x 100 mm) in size illustrating finish and color.
E.
Submit
maintenance data for installed products in accordance with Section
01780-Closeout Submittals.
1.05
DELIVERY,
STORAGE AND HANDLING
A.
Generally
comply with provisions of Section 01600-Product Requirements.
B.
Comply
with manufacturer’s ordering instructions and lead time requirements to avoid
construction delays.
C.
Deliver
materials in manufacturer’s original, unopened, undamaged containers with
identification labels intact.
D.
Store
lockers indoors, protected from weather conditions and construction activities.
1.06
PROJECT
CONDITIONS
A.
Building
enclosed, completely protected from outside weather with minimum inside
temperature of 60°F.
1.07
WARRANTY
A.
Provide
manufacturer’s twenty year warranty against rust, delamination or breakage of
plastic components.
2.01
MANUFACTURERS
A.
The
Mills Company, a subsidiary of Bradley Corporation, P.O. Box 309, Menomonee
Falls, WI 53052-0309. Phone 800-BRADLEY
(800-272-3539), FAX 262-251-5817.
http://www.bradleycorp.com
B.
Substitutions:
[Comply with Section 01600 – Product Requirements] [Not Permitted].
2.02
MANUFACTURED
UNITS
A.
Model
LENOXLOCKER lockers, [60 inch (1524 mm)] [72 inch (1829 mm) high x [12 inch
(305 mm)] [15 inch (381 mm)] [18 inch (457 mm)] wide x [12 inch (305 mm)] [15
inch (381 mm)] [18 inch (457 mm) deep, [1] [2] [3] [4] [5] tier [6 tier (72 inch model only)], (specify from standard and optional
selections).
B.
Model
LENOXBENCH bench lockers, 20 inch (508 mm) high x 12 inch (254 mm) wide x 10
inch deep, (specify from standard and
optional selections).
C.
Model
LENOXCUBBY cubby lockers, [60 inch (1524 mm)] [72 inch (1829 mm)] high x [12
inch (305 mm)] [15 inch (381 mm)] [18 inch (457 mm) wide x [12 inch (305 mm)]
[15 inch (381 mm)] [18 inch (457 mm) deep, [2] [3] [4] [5] tier [6 tier (72 inch model only)], (specify from standard and optional
selections).
D.
Model
LENOXPEDSTAL pedestal bench, 20 inch (508 mm) high x 9 1/2 inch (241 mm) wide, (specify from standard selections).
2.03
COMPONENTS
A.
Locker
material: Sides, backs, shelves, tops, bottoms, doors, door frames and
continuous latch constructed from high-density polyethylene (HDPE).
1.
Sides,
shelves, tops, bottoms and backs fabricated from 3/8 inch (10 mm) HDPE.
2.
Doors,
door frames and continuous latch fabricated from ½ inch (13 mm) HDPE.
3.
Slope
tops fabricated from 1/2 inch (13 mm) HDPE sheets, and 1 inch (25.4 mm) HDPE
back plates.
4.
Bases
fabricated from 1 inch (25.4 mm) HDPE.
5.
End
panels fabricated from 3/8 inch (10 mm) HDPE.
6.
Flat
tops fabricated from ½ inch (13 mm) HDPE.
B.
Door
hinge: Continuous piano hinge fabricated from 16 gauge type 304 stainless
steel.
C.
Pedestal
bench: Top fabricated from 1 1/2 inch (38 mm) thick HDPE, pedestals 18 ½ inch
(470 mm) black anodized aluminum with welded aluminum flanges.
D.
Locker
bench top: 1 inch (25 mm) thick HDPE.
2.04 HARDWARE
AND ACCESSORIES
A.
Provide
one plastic double coat hook for each opening in one and two tier lockers.
B.
Provide
one number plate for each opening.
C.
Provide
screws, anchors and angle brackets for locker base installation.
D.
Provide
hardware for attaching bench top to pedestals and anchoring pedestals to floor.
2.05 FABRICATION
A.
Locker
box fabricated from a single sheet of HDPE with corners fused together. Weld frame and shelves to box assembly.
B.
Attach
hinge to door and frame with vandal-resistant double threaded stainless steel
screws.
C.
Continuous
latch securely attached to the entire length of the door with stainless steel
screws, providing a full length latching mechanism capable of accepting several
lock types.
D.
Fabricate
slope top from HDPE with a backing strip for attachment to wall.
E.
Locking
device: [Hasp] [Key lock] [Built-in combination lock][Coin/token operated
lock][card operated lock].
F.
Provide
[openings at top and bottom of each door] [mesh door] for ventilation.
G.
Base:
[3] [4] inch high.
H.
End
panels: [Flat top] [Slope top] for [single] [double] locker configuration.
I.
Factory
finish:
1.
Tops,
bottoms, side walls, backs, shelves, and continuous latch, smooth white
commercial grade.
2.
Door,
and door frames, slightly textured matte finish, color selected from manufacturer’s
standard.
3.
Hinge
powdercoated to match door and frame.
4.
Base
color: [Black] [(select special color)].
5.
End
panel color selected from manufacturer’s standard.
3.01
EXAMINATION
A.
Verify
that locker area is ready for installation.
B.
Verify
field measurements are as shown on approved shop drawings.
C.
Verify
that bases are properly, leveled, sized and in correct location.
D.
Verify
correct location of built-in framing and blocking.
3.02
INSTALLATION
A.
Comply
with manufacturer’s written instructions for installation of lockers [and
bases]. Install plumb and square.
B.
Anchor
locker units to wall through the locker back with suitable anchor devices for
the substrate.
C.
Anchor
locker units to floor [base for island
applications] with hardware furnished by manufacturer.
D.
Through-bolt
adjoining locker units together to provide rigid installation.
E.
Install
accessories, [number plates,] [end panels,] [sloped tops,] [and flat tops].
3.03
ADJUSTING
A.
Section
01700 – Execution Requirements: Testing, adjusting, and balancing.
B.
Adjust
and align components to operate smoothly.
C.
Correct
minor damage to installed products; remove and replace work that cannot be
satisfactorily repaired.
3.04
CLEANING
A.
Section
01700 – Execution Requirements: Final cleaning.
B.
Clean
locker interiors and exterior surfaces.
C.
Remove
packaging and construction debris, and legally dispose of off-site.
3.05
SCHEDULE
(Where specified locker units vary in tier
number, depth, color, etc., it might be best to give them a “mark” and create a schedule).